i
Vanzetti logo

VT-55Series

Cryogenic Reciprocating Pumps for Liquefied Natural Gas (LNG) & Industrial Gases

These data must be considered indicative and subject to the confirmation by our Engineering Department.

Performances. Please enter a range value to know the pumps you need.

Models.

VT-55 TW 10 PistonBoreStroke Flow-rateMin 150* rpmMax 450 rpm Maximum allowable suction pressure (MASP) Maximum allowable working pressure (MAWP) Power installedReferedded
to MAWP
Series pump mm mm lpm gpm lpm gpm bar psi bar psi kW
VT-55 62 S 55 62 20 5,3 59,5 15,7 20 290 420 6092 37 - 110 NPSH required: 1,5 - 1,7 m * flow-rate can be reduced by forced oil lubrication system
VT-55 62 D 55 62 40 10,6 119 31,4 20 290 420 6092 45 - 132 NPSH required: 1,5 - 1,7 m * flow-rate can be reduced by forced oil lubrication system
VT-55 62 T 55 62 60 15,9 179 47,3 20 290 420 6092 72 - 200 NPSH required: 1,5 - 1,7 m * flow-rate can be reduced by forced oil lubrication system
NPSH required: 1,5 - 1,7 m
*flow-rate can be reduced by forced oil lubrication system

Features & Informations.

close
close
  • Compatible with Cold Converter and Thermosyphon storage tanks
  • Modular assembly (from Simplex to Triplex)
  • High efficiency
  • Low operating noise
  • Quick maintenance thanks to the integrated cartridge seal system
close
  • Flushing system with nitrogen gas
  • Electrical control panel
  • 2 speed electric motor
  • Motor suitable for VFD
  • Complete automatic system available on demand
close
  • Big sized L-CNG refueling stations for cars/trucks/buses, mother stations, tube trailer filling
close
  • Dimensional control of each mechanical component before assembly
  • Running test of each pump with LIN before delivery
close
Designed according to:
  • European Directive Machinery
  • European Directive PED
  • European Directive ATEX*
  • EIGA/IGC/CGA guidelines
  • *VT-55 Skids are ATEX certified.
 Download product details

Our team is at your disposal for all kinds of requests.