Serie DVM

POMPE CRIOGENICHE ALTERNATIVE per GAS INDUSTRIALI

Modelli.

Serie DVM

DVM 185-2S
Modelli Potenza installata (Motor frame) Velocità operativa massima (90Hz) Pressione d'aspirazione massima Massima pressione operativa Prevalenza massima Portata massima Peso (Motor Frame)
Serie di pompe Pm [kW] RPM P [bar] MAWP [bar] DH [m] Q [lpm] W [Kg]
DVM 185-2S 11 – 15 - 18,5 - 22 (160L) / 30 - 37 (180L) 5200 5 35 280 520 325 (160L) / 440 (180L)
I dati possono essere soggetti a modifiche

Caratteristiche & Informazioni

close
close
  • Available in single stage or multistage configuration
  • Electric motor with direct transmission
  • Piloted by variable frequency drive for different speeds and operating points
  • Cartridge labyrinth gas seal (single or double type)
  • Low sealing gas consumption required
  • Purged bearing grease retaining chamber
  • Purged warm box
  • Composite insulating flange
  • Inducer to minimize required NPSH
  • Low noise emission (< 80 dB)
close
  • PT100 for monitoring the motor front bearing temperature
  • Front motor bearing heating belt
  • Suction filter
  • Suction and discharge flexible hoses
close
  • Continuous processes with industrial gases
  • Air separation units (ASU)
  • Recycling
  • Liquid transfer between storage tanks
  • Process and backup operations
close
  • Dimensional control of each mechanical component before assembly
  • Running test of each pump with LIN before delivery
close
Designed according to:
  • European Directive
  • EIGA/IGC/CGA guidelines

Il nostro team è a vostra disposizione per ogni tipo di richiesta.